+61 2 4320 6670 sales@crealt.com.au
Select Page

Xenocs Accessories

Sample holders & handling

In addition to the standard stages delivered with each system, we offer a range of specialized sample holders for our SAXS/WAXS instruments.

Low noise flow cell

For liquid samples, especially useful for dilute or low scattering samples.

Description
Vacuum compatible low scattering flow cell with feedthroughs to inject the liquid sample. Compatible with multipurpose temperature stage.

Instrument
Nano-inXider, Xeuss

Note
Above photograph shows the Xeuss version of the sample holder.

Capillary flow cell

For liquid samples.

Description
Vacuum compatible glass capillary flow cell with feedthroughs to inject the liquid sample.

Instrument
Nano-inXider, Xeuss

Note
Above photograph shows the Xeuss version of the sample holder.

Autosampler for liquids

For automatic and high precision liquid sample injection in the flow cells (using tubing connections).

Description
Temperature controlled (4 to 40°C) sample changer with capacity of 2 x 48 or 2 x 96 vials. Can be used with the low noise flow cell and the capillary flow cell.

Instrument
Nano-inXider, Xeuss

BioCube

Measurement cell for low sample volume solution scattering with machine vision assisted sample positioning.

Description
Optional UV-Vis. Compatible with SEC-SAXS and BioXolver pipetting robot. Temperature controlled.

Instrument
BioXolver, Xeuss

Note
Above photograph shows the BioCube in use in the BioXolver instrument.

BioXolver pipetting robot

Robot for use with BioCube.

Description
2x 96 (or 384) well trays with optional temperature control. Tubeless sample handling. No cross-contamination with disposable pipette tips. Full software integration.

Instrument
BioXolver, Xeuss

Note
Above photograph shows the BioXolver pipetting robot in use in the BioXolver instrument.

Gel and powder capsule holder

For powders and gels, also suitable for liquids.

Description
Rack of 8 cells mounted on magnets for easy positioning.

Instrument
Xeuss, Nano-inXider

Note
Above photograph shows the Nano-inXider version of the sample holder.

Advanced GISAXS sample holder

For studying nanostructured surfaces and thin films.

Description
Sample stage designed to measure in grazing incidence geometry, offering multiple degrees of freedom for optimal sample alignment. Compatible with high temperature stage.

Instrument
Nano-inXider, Xeuss

Note
Above photograph shows the Xeuss version of the standard sample holder.

Sample Environments

Xenocs provides a wide choice of sample environments to study samples under non-ambient conditions.
These are available from us only as accessories to our SAXS/WAXS instruments.

Temperature

Multipurpose temperature stage

For temperature control of interchangeable multi-sample holders.

Description
Peltier type temperature stage with water cooling to control the temperature of several samples simultaneously.

Range
-30 °C to 150 °C, limited to 4 °C to 50 °C for liquid samples.

Vacuum compatible
Yes

Compatible samples
Delivered with multi-sample holders for solids (16 positions), capillaries (9 positions), powders (16 positions). Compatible with low noise flow cell thermalization.

Instrument
Nano-inXider, Xeuss

High temperature sample stage

For temperature dependent studies.

Description
Temperature stage. Liquid nitrogen required for cooling below ambient.

Range
Operating temperature range: -150 °C to 350 °C

Vacuum compatible
Yes

Compatible samples
Solids, powders, gels, liquids in capillaries. Compatible with GISAXS stages.

Instrument
Nano-inXider, Xeuss

Extended high temperature stage

For temperature dependent studies on solids up to 1000°C.

Description
High temperature stage.

Range
Operating temperature range: ambient to 1000 °C.

Vacuum compatible
Yes

Compatible samples
Solids

Instrument
Nano-inXider, Xeuss

Multi refillable capillary holder with temperature control

For sample measurements where precise background subtraction is required.

Description
Temperature controlled stage allowing to mount up to 6 refillable capillaries. Since the capillaries are refillable, background measurement can be performed using the same capillary as for the sample measurement.

Range
Operating temperature range: -10°C to 80°C, limited from 5°C to 70°C for aqueous samples.

Vacuum compatible
Yes

Compatible samples
Liquids, gels, powders

Instrument
Nano-inXider, Xeuss

Tensile, Shear, Humidity

Tensile stage

For tensile stress and temperature dependent studies.

Description
Tensile stage.

Range
Temperature: -150 °C to +250 °C.

Force
0 – 200 N with 0.01 N resolution or 0 – 20 N with 0.001 N resolution.

Vacuum compatible
Yes

Compatible samples
Foils

Instrument
Nano-inXider, Xeuss

Xenocs Couette stage for shearSAXS

For structural studies of complex fluids under controlled shear.

Description
Integrated into the Xeuss 3.0 platform. Cylindrical Couette cell design with cylindrical rotor and stator made of low scattering polycarbonate material.

Range
Typical temperature range : +10°C to +65°C
Typical shear rate : 0.2 s-1 to 1020 s-1

Vacuum compatible
No

Compatible samples
Polymers, suspensions (colloids, emulsions, pastes), liquids and gels

Instrument
Xeuss 3.0

Plate-plate shear stage

For structural studies of viscous samples under controlled shear up to high temperatures.

Description
Integrated into the Xeuss platform. Provided with X-ray transparent windows for in-situ measurements of complex liquids under controlled shear (steady or oscillatory) and temperature.

Range
Temperature range ambient to 180°C (optionally -50 to 180°C on Cryo CSS450 delivered with liquid nitrogen).

Vacuum compatible
No

Compatible samples
Polymers, suspensions (colloids, emulsions, pastes)

Instrument
Xeuss

Humidity stage

For SAXS measurements of samples under controlled temperature/humidity conditions.

Description
Integrated relative humidity stage system.

Range
Provides relative humidity control (in air only) in the range between 10 % and 90 % for temperatures from ambient to 60 °C.

Vacuum compatible
No

Compatible samples
Solids

Instrument
Xeuss

NATIONAL OFFICE

Crea Laboratory Technologies
U4/4 Teamster Close
PO Box 3791
TUGGERAH NSW 2259
T: +61 2 4320 6670

GET SOCIAL

PHONE

NSW: +61 2 4320 6672
VIC: +61 3 9017 4496
QLD: +61 7 3333 2171
WA: +61 8 6465 4576
NZ: +64 212 372 731

ISO CERTIFICATION